How to Compare Allulose Purity Results Between Suppliers
Release time:
Nov 16,2026
Author:
Zhongda
Source:
Zhongda
Suppose two offers report 99.4% and 99.0% allulose. The assay basis and method decide whether that difference is real and whether it matters to the formulation. Start the comparison there, before ranking the suppliers.
Zhongda's public GRN 1309 filing contains assay and moisture results for three historical crystalline powder lots and three syrup lots, with the methods used to describe those materials. Our quality team can connect a proposed sample with the available factory data and discuss any additional independent analysis needed for supplier qualification. Zhongda's filing in the FDA GRAS inventory.
Put both assay results on a mass basis
“99.4% dry basis” means 99.4 g of allulose per 100 g of dry ingredient, if the method reports a calibrated mass fraction. “99.0% as supplied” means 99.0 g per 100 g of delivered ingredient. A statement such as “99% of total sugars” uses another denominator. To express it as g per 100 g of ingredient, the calculation needs a compatible total-sugar mass result for that sample. If the percentage was calculated from chromatographic peak areas, the calibration and detector responses also need to be resolved.
Here is a hypothetical comparison between two crystalline powder lots. Assume the assay results are mass fractions, the relevant moisture was measured for each lot and both methods are comparable. The values are teaching figures.
| Quoted lot | Reported assay and moisture | Comparison on a shared basis |
|---|---|---|
| A | 99.4% dry basis, 0.8% moisture | 99.4% × 0.992 ≈ 98.6% as supplied |
| B | 99.0% as supplied, 0.4% moisture | 99.0% ÷ 0.996 ≈ 99.4% dry basis |
The dry basis results are both about 99.4% at the precision of the original inputs. On an as supplied basis, lot B contains about 0.4 kg more allulose per 100 kg of ingredient in this example. Retain both the original results and the calculation. Whether that difference should affect an order depends on the method uncertainty and on what matters to the formulation.
A basis conversion needs the lot's applicable dry fraction. With loss on drying, the quality reviewer should establish whether the method's mass loss defines the dry basis used by the assay. Syrup likewise needs a compatible dry solids determination. A standard °Brix reading reflects refractive index on a sucrose scale, so it cannot by itself supply an allulose mass fraction.

Read the chromatogram with the method
HPLC is a family of methods. Two labs can both list HPLC on a COA and still use different columns, detectors, calibration or integration rules. The method for an offered allulose grade should account for residual fructose, glucose and other sugars that could affect the composition brief or overlap the allulose signal.
For example, the public Daesang GRAS notice 1148 shows HPLC with refractive index detection and chromatograms for a mixed sugar reference, an allulose crystal and a syrup. Those figures show how a method can document the separation behind a result. The laboratory and supplier still need to establish the method for the ingredient being assessed. Daesang GRAS notice 1148.
An assay calibrated against an allulose reference material answers a mass question when the method uses the weighed sample, dilution and reference response to calculate concentration. An area percentage expresses the share of integrated signal under the method's conditions. The two percentages can differ when responses vary, peaks overlap or components sit outside the integration window. Moisture correction alone cannot resolve that difference.
| What comes back from the supplier | What to request before scoring the result |
|---|---|
| “99% purity” or “HPLC 99%” | Analyte, reporting basis, method reference and revision, and whether 99% is a batch result or a specification limit. |
| Percent of measured sugars | The defined total and its measured mass fraction on a compatible basis. These are needed to convert the share into g per 100 g of ingredient. |
| Chromatographic area percent | Calibration, detector response and integration rules. Establish suitable mass based assay data for a specification written in g per 100 g. |
| Fructose listed as below a limit | Reporting limit, units and basis, with method sensitivity sufficient for the purchasing limit. |
| Two results that straddle your limit | Unrounded results where available, method performance near the limit and the agreed decision rule. Resolve these before scoring the difference. |
Split one identified lot when methods disagree
If the supplier reports disagree, changing supplier and method at the same time makes the difference hard to explain. A representative sample from one identified lot, split into sealed portions under an agreed plan, gives the quality teams a more direct comparison. The sample record links the lot, sampling date, storage conditions and aliquot identifiers. Each laboratory reports its assay and moisture or dry solids result with the methods used.
If the discrepancy remains, agree a referee laboratory, a method suitable for that allulose form and the decision rule near the limit. A repeat injection from the same preparation examines instrument repeatability. Independently prepared portions also examine variation from sample preparation. Choose the work that addresses the unresolved source of variation. Eurachem guide to analytical method validation.
For the shipment itself, the purchase specification and lot record still have to match. See how to review an allulose certificate of analysis at receipt.
Work with Zhongda's quality team
The FDA response to Zhongda's GRAS notice 1309 describes minimum assays of 98% for the notified crystalline powder and 95% for the notified syrup, both on a dry weight basis. FDA had no questions about Zhongda's GRAS conclusion for the intended conditions of use in the notice. FDA response to GRN 1309.
The filing lists FCC HPLC for the assay and GB 5009.3 vacuum drying for moisture. Three historical crystalline powder lots measured 99.2, 99.4 and 99.3 g of allulose per 100 g dry material. One syrup lot paired 98.5 g per 100 g dry material with 29.8 g moisture per 100 g of syrup. Using that lot's reported moisture to establish the dry fraction gives 98.5 × 0.702 ≈ 69.1 g of allulose per 100 g as supplied. This is a calculated value for the historical lot. Compare offers using the current commercial specification and the report for the lot you are evaluating. Zhongda GRN 1309 filing, Tables 2.4.1 and 2.4.2.
Zhongda connects allulose manufacturing with factory QC reporting and independent reporting options, including SGS. Our capability profile identifies the QC center as CNAS accredited. For work requiring an accredited report, the agreed laboratory and current scope must cover the proposed analyte, method and matrix. The report arrangement can then be settled alongside the sample and purchasing specification. Zhongda's quality and research facilities.
We also support custom specifications and sweetener blends for sugar reduction projects. A blend needs its own grade identity, with the allulose target expressed against the mass of the offered blend. Bring that composition requirement into the first assay discussion so the laboratory answers the question the formulator needs resolved.

Send the grade and reports you want to compare, together with your required reporting basis and acceptance limit. Zhongda's team can discuss the identified sample, available factory data and any independent work needed for that purchasing decision. View Zhongda's D-Allulose forms and request an allulose sample and assay discussion.
Recommend News




